AIM200 - O-NW25, Active Inverted Magnetron Gauge, D2G0021130

Onderdeelnummer:D2G0021130
EUR 1,545.00

Variant

Bekijk de onderstaande varianten om het product te vergelijken

Korte beschrijving Onderdeelnummer Connection Inlet Flange Weight Dimension Length Connector Electrical Power Recommended Controller Competitor Gauge Replacement Variant Gauges Certificated Pressure Measurement Device Communication Interfaces Customer Aansluiting Elektrische Communicatie Interface Connector Setpoint Quantity Communication Interface Protocol
D2G0021100 DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - linear) RJ45 (FCC 68) - Female 0 2.0 - 10 V log linear with pressure AIM200
D2G002110C DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - linear) RJ45 (FCC 68) - Female 0 2.0 - 10 V log linear with pressure AIM200
D2G0021120 DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G002112C DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G0021130 DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G002113C DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G0021140 DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G002114C DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G0021150 DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - Edwards - internal standard AIM200-S (S - S-shape analog output - check for setpoints) Standard OEM 0-10 V (analog output - S-shape) RJ45 (FCC 68) - Female 0 2.0 - 10 V S-shape with pressure AIM200
D2G002115C DN 25 ISO-KF (NW25) 0.350 0.092 RJ45 (FCC 68) - Female - Edwards - internal standard AIM200-S (S - S-shape analog output - check for setpoints) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - S-shape) RJ45 (FCC 68) - Female 0 2.0 - 10 V S-shape with pressure AIM200
D2G0031100 DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - linear) RJ45 (FCC 68) - Female 0 2.0 - 10 V log linear with pressure AIM200
D2G003110C DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - linear) RJ45 (FCC 68) - Female 0 2.0 - 10 V log linear with pressure AIM200
D2G0031120 DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G003112C DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G0031130 DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G003113C DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G0031140 DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G003114C DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G0031150 DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - Edwards - internal standard AIM200-S (S - S-shape analog output - check for setpoints) Standard OEM 0-10 V (analog output - S-shape) RJ45 (FCC 68) - Female 0 2.0 - 10 V S-shape with pressure AIM200
D2G003115C DN 40 ISO-KF (NW40) 0.380 0.092 RJ45 (FCC 68) - Female - Edwards - internal standard AIM200-S (S - S-shape analog output - check for setpoints) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - S-shape) RJ45 (FCC 68) - Female 0 2.0 - 10 V S-shape with pressure AIM200
D2G0041100 DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - linear) RJ45 (FCC 68) - Female 0 2.0 - 10 V log linear with pressure AIM200
D2G004110C DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - linear) RJ45 (FCC 68) - Female 0 2.0 - 10 V log linear with pressure AIM200
D2G0041120 DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G004112C DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G0041130 DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G004113C DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G0041140 DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G004114C DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female 0 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G0041150 DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - Edwards - internal standard AIM200-S (S - S-shape analog output - check for setpoints) Standard OEM 0-10 V (analog output - S-shape) RJ45 (FCC 68) - Female 0 2.0 - 10 V S-shape with pressure AIM200
D2G004115C DN 40 CF (2.75") 0.630 0.098 RJ45 (FCC 68) - Female - Edwards - internal standard AIM200-S (S - S-shape analog output - check for setpoints) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - S-shape) RJ45 (FCC 68) - Female 0 2.0 - 10 V S-shape with pressure AIM200
D2G0121200 DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - linear) DSUB 9-PIN - Male 1 2.0 - 10 V log linear with pressure AIM200
D2G012120C DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - linear) DSUB 9-PIN - Male 1 2.0 - 10 V log linear with pressure AIM200
D2G0121220 DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G012122C DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G0121230 DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G012123C DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G0121240 DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G012124C DN 25 ISO-KF (NW25) 0.350 0.092 DSUB 9-PIN - Male - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G0131200 DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - linear) DSUB 9-PIN - Male 1 2.0 - 10 V log linear with pressure AIM200
D2G013120C DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - linear) DSUB 9-PIN - Male 1 2.0 - 10 V log linear with pressure AIM200
D2G0131220 DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G013122C DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G0131230 DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G013123C DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G0131240 DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G013124C DN 40 ISO-KF (NW40) 0.380 0.092 DSUB 9-PIN - Male - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G0141200 DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - linear) DSUB 9-PIN - Male 1 2.0 - 10 V log linear with pressure AIM200
D2G014120C DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male TIC - Instrument Controller ADC - Gauge Controller TAG - Turbo & Instrument Controller Edwards - internal standard AIM200-X(S) (X - linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - linear) DSUB 9-PIN - Male 1 2.0 - 10 V log linear with pressure AIM200
D2G0141220 DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G014122C DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male - Inficon AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (0.667 to 10.0 V Inficon log linear with pressure (G))
D2G0141230 DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G014123C DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male - Pfeiffer Vacuum AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
D2G0141240 DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Standard OEM 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))
D2G014124C DN 40 CF (2.75") 0.630 0.098 DSUB 9-PIN - Male - MKS Instruments AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint)) Internal Factory Calibrated (Certificate included) 0-10 V (analog output - matched output) DSUB 9-PIN - Male 1 Matched cold cathode (1.5 to 4.4375 V MKS from log linear with pressure (Q))

Meter Indirecte Drukmeting

Indirecte breedbereik vacuümmeters zijn de beste keuze wanneer de druk over een breed bereik moet worden gemeten en wanneer goede nauwkeurigheid over het hele bereik nodig is. Betrouwbare vacuümmeters zijn essentieel om de nauwkeurigheid en controle van uw systeem te waarborgen. Onze vacuümmeteroplossingen omvatten de WRG-serie Cold Cathode Combination Gauge, AIM-serie Cold Cathode Gauge en APG-serie Pirani Gauge.

AIM Serie Koudkathode Meter

De nieuwe Active Inverted Magnetron Gauge AIM200 van Edwards is robuust en betrouwbaar en door zijn compacte formaat, 360 graden LED-lichtring, geïntegreerde setpoints en flexibiliteit van aansluitingen/uitgangen, geschikt voor een breed scala aan toepassingen, van wetenschappelijke instrumenten tot industriële processen. De AIM200 meetkop en de meetregelaar zijn gecombineerd in één compact apparaat en hebben een zeer laag strooiveld, gecombineerd met een kleiner oppervlak en een verbeterd ontstekingsmechanisme, waardoor het de perfecte keuze is voor gebruik in analytische toepassingen waar de meter in de nabijheid van gevoelige apparatuur moet worden gemonteerd.

Features and Benefits

  • 360° LED lichtring visuele drukindicator
  • Verminderde voetafdruk
  • Meerpunt sterstaker
  • Analoog/digitaal
  • Breedbandvoeding
  • Compatibel met bestaande systemen
  • Nieuwe magneten
  • Setpointrelais

Algemene productinformatie

Connection Inlet Flange DN 25 ISO-KF (NW25)
Weight 0.350
Voedingsspanning DC 15-48V
Dimension Length 0.092
IP Rating IP40
Voedingsfrequentie DC Voltage
Dimension Height 0.046
Dimension Width 0.045
Connector Electrical Power RJ45 (FCC 68) - Female
Dimensie Opmerkingen De afmetingen lengte, breedte en hoogte proberen de buitenvorm van dit specifieke product in zijn typische oriëntatie weer te geven wanneer het op de grond staat. We raden altijd aan om de gedetailleerde afmetingen te controleren in de 2D-tekeningen in de handleiding of de 3D-vormen in de 3D-modellen.

Omgevingsomstandigheden

Temperature Ambient Operation Max 333.15
Temperatuur Omgeving Bedrijf Min 278.15
Temperature Ambient Storage Min 243.15
Temperature Ambient Storage Max 343.15

Classificatie

Classification Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Classification Principle of Measurement Cold-cathode vacuum gauge (IM inverted magnetron)
Competitor Gauge Replacement Pfeiffer Vacuum
Level of Gauge Accuracy Medium
Classification Guage for Corrosive Gases No

Constructiemateriaal

Material Body Stainless Steel 1.4404 / 316 L / X2 CrNiMo 17 13 2
Materiaal Blootgesteld aan Vacuüm Roestvrij staal 316L en 304L, glas, molybdeen, spoor van nikkel en nikkelijzer
Material Filament Tungsten/Rhenium

Bedrijfsomstandigheden - Beperkingen

Inlaat Absolute Druk Continu Max 1.500 × 10⁵
Temperature Baking Max (Elec. Removed) 423.15
Pressure Inlet Max Overpressure 1.000 × 10⁶
Temperature Baking Max 323.15
Altitude Max 3000.00

Prestatiegegevens

Measurement Uncertainty 1x10-2 to 1x10-8 mbar ±30%
Maximaal stroomverbruik 4W
Drukmeting Max 1.00
Drukmeting Min 1.000 × 10⁻⁷

Varianten

Variant Gauges AIM200-G/O/Q(S) (Matched to competitor standard output, linear 0-10V output, (setpoint))
Certificated Pressure Measurement Device Standard OEM

Connectiviteit - Communicatie-interface

Communication Interfaces Customer 0-10 V (analog output - matched output)
Aansluiting Elektrische Communicatie Interface Connector RJ45 (FCC 68) - Female
Setpoint Quantity 0
Status Indicator LED Light Ring
Communication Interface Protocol Matched cold cathode (1.5 to 8.5 V Pfeiffer & Inficon from 1x10-9 to 1x103 log linear with pressure (O)) MPG500/504/400/401 & PKR360/361/251/261
Product Titel Onderdeelnummer Prijs In winkelwagen
Spare AIM200-O RJ45 Electronics (Podule), ZD2GA0A1130 ZD2GA0A1130 EUR 899.00
Spare tube AIM200 - NW25, ZD2G0A2AAA0 ZD2G0A2AAA0 EUR 867.00