T-Piece Reducing - St St NW25 - NW16

Part Number: C10514427

0 In Stock

Click For Availability Typical lead time 1 week(s)

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Connection Vacuum Flanges Classification Product Pressure Range
C10514427 DN 25 ISO-KF (NW25) DN 25 ISO-KF (NW25) DN 16 ISO-KF (NW16) Medium Vacuum: 1 mbar - 1·10⁻³ mbar Rough Vacuum: 1000 mbar - 1 mbar High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
C10516428 DN 40 ISO-KF (NW40) DN 40 ISO-KF (NW40) DN 16 ISO-KF (NW16) Medium Vacuum: 1 mbar - 1·10⁻³ mbar Rough Vacuum: 1000 mbar - 1 mbar High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
C10516429 DN 40 ISO-KF (NW40) DN 40 ISO-KF (NW40) DN 25 ISO-KF (NW25) Medium Vacuum: 1 mbar - 1·10⁻³ mbar Rough Vacuum: 1000 mbar - 1 mbar High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
C10517430 DN 50 ISO-KF (NW50) DN 50 ISO-KF (NW50) DN 16 ISO-KF (NW16) Medium Vacuum: 1 mbar - 1·10⁻³ mbar Rough Vacuum: 1000 mbar - 1 mbar High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
C10517431 DN 50 ISO-KF (NW50) DN 50 ISO-KF (NW50) DN 25 ISO-KF (NW25) Medium Vacuum: 1 mbar - 1·10⁻³ mbar Rough Vacuum: 1000 mbar - 1 mbar

ISO-KF Piping Components

When you buy vacuum pump components from Edwards, you can expect the quality and service that only a leading international supplier can provide. We understand that flanges and fittings are critical to the performance of your vacuum system, and supply only high quality products which meet the highest specification.

NW fittings, otherwise known as ISO-KF, are the industry standard for many applications in the low to high vacuum range. They are ideal for achieving dependable cost effective performance down to 10-7 mbar across a range of applications from light to harsh duty. A simple fastening method means that systems can be easily assembled and a leak tight vacuum seal is quickly achieved.

Our components and flange fittings are designed to be leak-tight across the range of vacuum applications, and not intended to provide full structural support. When designing any vacuum system, it is essential that consideration is given to the static and dynamic loads imposed on each connection. If necessary, additional mechanical support should be provided and built into the design. Regular inspection including leak-checking and, where appropriate, periodic replacement of components should be considered to ensure system efficiency and safety is maintained.

Features and Benefits

  • Convenience of supply - Single source supplier, able to provide the complete system solution either online or via local supply centres.
  • High quality and reliability - Precision material control ensures a dependable vacuum performance on sensitive or demanding applications.
  • Comprehensive choice - Complete range for all common flange sizes in aluminium and stainless steel.
  • Manufactured to ISO 2861 and DIN 28403 standards
  • Nominal diameters 10 to 50 mm
  • Use with either elastomer or formed aluminium seals
  • Choice of clamp type depending on application, access, convenience and cost
  • For use in high-vacuum applications: pressures > 10-8 mbar

Environmental Conditions

Temperature Ambient Operation Max 623.15
Temperature Ambient Operation Min 77.15

General Product Information

Connection Vacuum Flanges DN 25 ISO-KF (NW25)
DN 25 ISO-KF (NW25)
DN 16 ISO-KF (NW16)
Recommended Pressure Range Min 1.000 × 10⁻⁵
Recommended Pressure Range Max 1.500 × 10⁵

Material of Construction

Material Body Stainless Steel 1.4404 / 316 L / X2 CrNiMo 17 13 2
Material of Construction Stainless Steel 1.4404 316L
Material Abbreviation St St

Classification

Classification Product Pressure Range Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Rough Vacuum: 1000 mbar - 1 mbar
High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Product Title Part Number Price Add to cart
APG200 - XM-NW16 D1G1011100 -
APG200 - M-NW16 D1G1011150 -
APG200 - OM-NW16-DB9 D1G1011230 -
APG200 - XMS-NW16 D1G1211100 -
APG200 - GMS-NW16 D1G1211120 -
APG200 - XLC-NW16 D1G2011100 -
APG200 - XLCS-NW16 D1G2211100 -
APG200 - GLCS-NW16 D1G2211120 -
APG200 - MP-NW16 D1G3011150 -
APG200 - XMPS-NW16 D1G3211100 -
APG200 - XM-NW16-CAL D1G101110C -
APG200 - XM-NW16-DB9-CAL D1G101120C -
APG200 - XMS-NW16-CAL D1G121110C -
APG200 - OMS-NW16 D1G1211130 -
APG200 - XMS-NW16-DB9 D1G1211200 -
APG200 - XMS-NW16-DB9-CAL D1G121120C -
APG200 - XLC-NW16-CAL D1G201110C -
APG200 - GLC-NW16-CAL D1G201112C -
APG200 - XLC-NW16-DB9-CAL D1G201120C -
APG200 - QLC-NW16-DB9-CAL D1G201124C -
APG200 - XLCS-NW16-CAL D1G221110C -
APG200 - OLCS-NW16-CAL D1G221113C -
APG200 - XLCS-NW16-DB9-CAL D1G221120C -
APG200 - XMP-NW16 D1G3011100 -
APG200 - XMP-NW16-CAL D1G301110C -
APG200 - XMPS-NW16-CAL D1G321110C -
APG200 - OMPS-NW16-CAL D1G321113C -
APG200 - XMPS-NW16-DB9 D1G3211200 -
APG200 - XMPS-NW16-DB9-CAL D1G321120C -
APG200 - OMPS-NW16-DB9 D1G3211230 -
APG200 - OMPS-NW16-DB9-CAL D1G321123C -
APG200 - QLC-NW16 D1G2011140 -
APG200 - GM-NW16 D1G1011120 -
APG200 - GM-NW16-CAL D1G101112C -
APG200 - OM-NW16 D1G1011130 -
APG200 - OM-NW16-CAL D1G101113C -
APG200 - QM-NW16 D1G1011140 -
APG200 - QM-NW16-CAL D1G101114C -
APG200 - M-NW16-CAL D1G101115C -
APG200 - XM-NW16-DB9 D1G1011200 -
APG200 - GM-NW16-DB9 D1G1011220 -
APG200 - GM-NW16-DB9-CAL D1G101122C -
APG200 - OM-NW16-DB9-CAL D1G101123C -
APG200 - QM-NW16-DB9 D1G1011240 -
APG200 - QM-NW16-DB9-CAL D1G101124C -
APG200 - GMS-NW16-CAL, Pirani Gauge, D1G121112C D1G121112C -
APG200 - OMS-NW16-CAL, Pirani Gauge, D1G121113C D1G121113C -
APG200 - QMS-NW16, Pirani Gauge, D1G1211140 D1G1211140 -
APG200 - QMS-NW16-CAL, Pirani Gauge, D1G121114C D1G121114C -
APG200 - GMS-NW16-DB9, Pirani Gauge, D1G1211220 D1G1211220 -
APG200 - GMS-NW16-DB9-CAL, Pirani Gauge, D1G121122C D1G121122C -
APG200 - OMS-NW16-DB9, Pirani Gauge, D1G1211230 D1G1211230 -
APG200 - OMS-NW16-DB9-CAL, Pirani Gauge, D1G121123C D1G121123C -
APG200 - QMS-NW16-DB9, Pirani Gauge, D1G1211240 D1G1211240 -
APG200 - QMS-NW16-DB9-CAL, Pirani Gauge, D1G121124C D1G121124C -
APG200 - GLC-NW16, Pirani Gauge, D1G2011120 D1G2011120 -
APG200 - OLC-NW16, Pirani Gauge, D1G2011130 D1G2011130 -
APG200 - OLC-NW16-CAL, Pirani Gauge, D1G201113C D1G201113C -
APG200 - QLC-NW16-CAL, Pirani Gauge, D1G201114C D1G201114C -
APG200 - LC-NW16-CAL, Pirani Gauge, D1G201115C D1G201115C -
APG200 - XLC-NW16-DB9, Pirani Gauge, D1G2011200 D1G2011200 -
APG200 - GLC-NW16-DB9, Pirani Gauge, D1G2011220 D1G2011220 -
APG200 - GLC-NW16-DB9-CAL, Pirani Gauge, D1G201122C D1G201122C -
APG200 - OLC-NW16-DB9, Pirani Gauge, D1G2011230 D1G2011230 -
APG200 - OLC-NW16-DB9-CAL, Pirani Gauge, D1G201123C D1G201123C -
APG200 - QLC-NW16-DB9, Pirani Gauge, D1G2011240 D1G2011240 -
APG200 - GLCS-NW16-CAL D1G221112C -
APG200 - OLCS-NW16 D1G2211130 -
APG200 - QLCS-NW16 D1G2211140 -
APG200 - QLCS-NW16-CAL D1G221114C -
APG200 - XLCS-NW16-DB9 D1G2211200 -
APG200 - GLCS-NW16-DB9 D1G2211220 -
APG200 - GLCS-NW16-DB9-CAL D1G221122C -
APG200 - OLCS-NW16-DB9 D1G2211230 -
APG200 - OLCS-NW16-DB9-CAL D1G221123C -
APG200 - QLCS-NW16-DB9 D1G2211240 -
APG200 - QLCS-NW16-DB9-CAL D1G221124C -
APG200 - GMP-NW16 D1G3011120 -
APG200 - GMP-NW16-CAL D1G301112C -
APG200 - OMP-NW16 D1G3011130 -
APG200 - OMP-NW16-CAL D1G301113C -
APG200 - QMP-NW16 D1G3011140 -
APG200 - QMP-NW16-CAL D1G301114C -
APG200 - MP-NW16-CAL D1G301115C -
APG200 - GMPS-NW16 D1G3211120 -
APG200 - GMPS-NW16-CAL D1G321112C -
APG200 - OMPS-NW16 D1G3211130 -
APG200 - QMPS-NW16 D1G3211140 -
APG200 - QMPS-NW16-CAL D1G321114C -
APG200 - GMPS-NW16-DB9 D1G3211220 -
APG200 - GMPS-NW16-DB9-CAL D1G321122C -
APG200 - QMPS-NW16-DB9 D1G3211240 -
APG200 - QMPS-NW16-DB9-CAL D1G321124C -
APG200 - LC-NW16 D1G2011150 -